This thermostat runs on a daily schedule. Each block of the day (sleep, wake, evening, β¦) has its own temperature bands β the heat and cool limits that decide when each room's unit turns on. The schedule and its bands are shown further down the page.
The Master Bedroom and Front Bedroom bands can be adjusted independently, but the schedule block timing is shared across the whole system.
Band adjustment
CURRENT selectedSet the heat and cool temperature limits for the chosen schedule block and room. Tap a band edge to type an exact value, or unlock Edit mode to drag it graphically. The Master / Front toggle picks which room you're editing (it also sets the room shown in the schedule below).
Tap a band edge to type an exact value. Unlock Edit mode to enable graphical dragging. Edits accumulate in a draft and are applied only when you click Save.
Today's schedule β Master bedroom
Tap a block (or a chip) to load it above. Tap a divider to type times. Unlock Edit mode to enable graphical divider dragging. Purge blocks (shaded) are locked.
System status
OFFLINEWhat the controller is doing right now, straight from its decision log β for troubleshooting, not control. Refreshes on the same cycle as the rest of the page.
Advanced controls
These affect the whole system β change them only if you understand the setup.
A per-unit Off turns the room off; turning it back on restores schedule-follow (not the mode it was in before).
While Manual, the thermostat sends no commands to master bedroom β control the unit yourself via the remote or Home Assistant. The front bedroom continues on its normal schedule.
While Manual, the thermostat sends no commands to front bedroom. The master bedroom continues on its normal schedule.
Turn the thermostat off to take manual control β the controller stops touching the units entirely, and they hold whatever state they're in until you change them by remote or the Home Assistant app. Turn it back on to resume the schedule. (While off, the automatic-only controls above have no effect.)
Normal conditions the master bedroom 5pmβ8:30am and leaves it off through the day. Baby holds a warm band around the clock. Medium Baby walks a warming ladder overnight and through the morning, then parks 11amβ6pm.
All three front presets condition 5pmβ9am and park 9amβ5pm; they differ only in the band. Wide band (eco) has the largest deadband β it heats lower and cools higher, so it runs least. Warm is Normal shifted up 2Β°F.
Runs the daily oil-return purge cycle at 4pmβ5pm. Turning it off drops those blocks from the schedule; Manual purge below still works either way.
Runs a one-off ~1-hour compressor purge (heat purge β dwell β cool purge β dwell β restore) on both units for oil return. In summer the heat purge is skipped automatically. You'll be asked to confirm first.